OPTION menu
Item Description
SERVICE
Selecting this item displays the SERVICE
menu. Highlight an item using the ▲/▼
buttons, and press the ► button or the
SELECT button on the remote control to
select the item.
FAN SPEED HIGH
Using the ▲/▼ buttons switches the rotation speed of the cooling
fans. If the projector is used at an altitude of 3937' (1200m) or higher,
select ENABLE. Otherwise select DISABLE. Note: The projector is
noisier when ENABLE is selected.
ENABLE
ó
DISABLE
AUTO IMAGE
Using the ▲/▼ buttons selects one of the modes. When the DISABLE
is selected, the automatic adjustment feature is disabled.
FINE
ó
FAST
ó
DISABLE
FINE: Provides ner tuning and includes TRACKING adjustment.
FAST
: Provides faster tuning and selects a particular TRACKING
based on the input signal.
• Depending on conditions, such as the input image, the signal
cable to the projector, the projector environment, etc., the automatic
adjustment may not work correctly. In this scenario, please choose
DISABLE to disable the automatic adjustment, and make adjustments
manually.
GHOST
1. Select a ghost color element using the
◄/► buttons.
2. Adjust the selected element using the ▲/▼
buttons to eliminate the ghosting.
RESET LAMP HOURS counts the time the lamp has been used since
it was last reset. Pressing the ► button of the projector displays the
reset dialog.
To reset the lamp hours, select OK using the ► button.
CANCEL
ð
OK
• Only reset the lamp hours when you have replaced the lamp in order
to preserve the accuracy of the lamp timer.
For lamp replacement instructions, see Replacing the lamp (
82).
RESET FILTER HOURS counts the time the air lter has been used
since it was last reset. Pressing ► button of the projector displays the
reset dialog. To reset the lter time, select OK using the ► button.
CANCEL
ð
OK
Only reset the lter time when you have cleaned or replaced the air
lter in order to preserve the accuracy of lter timer.
• For air lter cleaning information, see Cleaning and replacing the
air lter (
84).