Maintenance
Cleaning and replacing the air lter
Please check and clean the air lter periodically. When the indicators or a
message prompts you to clean the air lter, comply with it as soon as possible.
This projector’s air lter consists of a lter cover and a lter unit with two types of
lter. If one or both of the lters are damaged or heavily soiled, replace the lter
unit with a new one.
Use the following part number when purchasing a new lter unit from your dealer.
Part number : MU06641 (Filter unit)
A lter unit also ships with replacement lamps.
Replace the lter unit when you replace the lamp.
Filter cover
Filter cover
knobs
Filter unit
Filter unit
knobs
Interlocking
parts
1.
Turn the projector off, and unplug the power
cord. Allow the projector to sufciently cool
down.
2.
Use a vacuum cleaner on and around the
lter cover.
3.
Grab and pull up on the lter cover knobs to
take the cover off.
4.
Press the knobs on the bottom of the lter
unit up slightly to unlock the bottom side
of the lter unit. Pull the center knob to
remove the lter unit.
5.
Use a vacuum cleaner on the projector's
lter vent and the outside of the lter unit.
6.
The lter unit consists of two parts. Press
down around the interlocking parts to
unlock them and separate the two parts.
7.
Use a vacuum cleaner on the inner side
of each lter unit part to clean them. If
the lters are damaged or heavily soiled,
replace them with new ones.
8.
Combine the two parts to reassemble the
lter unit.
9.
Put the lter unit back into the projector.
(continued on next page)